Evaportive cooling 18000

 

18000 air duct machine/inverter single speed/fixed axial down air discharge

 

Model:FAD18-ER

 parameter/personalized setting

 

particular configuration

1

largest airflow(m³/h)

18000

1

sunshine resist PP machine cover(100%new material)

2

air outlet direction

down

2

three-phases 24 axis copper coiling wire motor

3

engineering noise(db)

≤75

3

nine-nylon blades

4

net weight(kG)

64

4

5090 high effect cooling pad

5

fault code prompt

5

cooling pads protective cover

6

motor insulation/protection degree

F/IP64

6

water diversion rigid PVC pipe

7

voltage/frequency(V/Hz)

380/50

7

open-type water diversion device

8

power(kW)

1.1

8

inflaming retarding control box

9

electric current(A)

2.6

9

single speed controller Moistureproof processing)

10

Range of climate

 -20℃~55℃

10

LCD screen control panel

11

machine length/width/height(mm)

1080/1080/980

11

15 m remote control

12

install machine chassis size(mm)

970×970

12

temperture and humidity sensor

13

with flange air outlet size(mm)

670×670

13

control panel/remote install pedestal

14

limit humidity setting

14

floating water inlet valve

15

Controller/Air flow pattern

LCD panel/remote control/single speed

15

ceramic axis water pump

16

moist area cooling area(m²)

80-150

16

fluent type drain pump

17

★duct air supply distance(m)

30

17

rocker type water sensor

18

direct air supply distance(m)

22

18

8m national standard signal wire

19

evaporative rate(%)

≈92

19

4m national standrad powr supply wire

20

Inlet pipe diameter

φ20

20

fan steel stainless support pole

21

Drainage pipe diameter

φ32

21

total steel stainless screw(fastener)

22

Fully automatic operation mode

22

galvanize air duct flange

23

cooling setting

23

steel net flange                                   (suggest optional spare part)

24

ventilational setting

24

steel stainless gauze element bracket  (optional spare part)

25

manual cleaning setting

25

water ultraviolet sterilization device     (optional spare part)

26

right/left automatic wind swing setting

26

PP dustproof net(optional spare part)

27

automatic drain setting(default 8 hours)

0~72hours/time

27

medium water filter

(optional spare part)

28

limit temperture machine switch setting

28

motor limit electric current protection

29

ultraviolet sterilization(default self-closing after operated 20 minutes)

after operated cooling setting□

29

water pump water shotage protection 

30

when the electricity comes again after  power failure, the  air cooler automatically starts.

30

water pump water temperture  protection 

 

 

 

31

power phase shortage protection

 

 

 

32

power voltage over/shortage protection

Explain:■ standard configuration   □ optional configuration    ★ optional key   S silence design  

▲ Engineering design please reference《OUBER Engineering product manual》and《OUBER product manual》depend on related applicable conditions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 